During an AODD wet-end rebuild, center disk orientation and material matter. Installing a non-beveled face against the diaphragm—or reversing air-side and wetted-side disks—can accelerate abrasion, corrosion and premature diaphragm failure.
Quick Troubleshooting TipHelpful Hints
Sep 10, 2026 Erik Vahl
During an AODD wet-end rebuild, center disk orientation and material matter. Installing a non-beveled face against the diaphragm—or reversing air-side and wetted-side disks—can accelerate abrasion, corrosion and premature diaphragm failure.
Helpful HintsDid You Know?Quick Troubleshooting Tip
Sep 01, 2026 robert@yamadapump.com
AODD pumps can tolerate dry running, but that doesn’t mean it should become normal operating practice. This article explains how dry running can accelerate component wear, increase compressed-air consumption, and raise maintenance costs—and outlines practical ways to prevent it using dry-run protection devices, liquid level controls, and pump controllers.
Did You Know?Quick Troubleshooting Tip
Aug 26, 2026 Erik Vahl
Learn common AODD pump failure causes, diaphragm and check-valve issues, preventive maintenance tips, and proper reassembly practices to reduce downtime.
Mar 18, 2020 paulr@yamadapump.com
If your air operated double diaphragm pump cycles and will not prime or there is no flow, try these troubleshooting tips below.