With the introduction of the XDP Series pumps we needed to use a proximity sensor other than the P1 and P2 sensors used on the rest of the Yamada product line, which sense the position of the C-Spool to count the cycles of the pump.
Jan 15, 2012 Paul Rainer
With the introduction of the XDP Series pumps we needed to use a proximity sensor other than the P1 and P2 sensors used on the rest of the Yamada product line, which sense the position of the C-Spool to count the cycles of the pump.
Oct 15, 2011 Paul Rainer
In August of 2008 the NDP-20 / NDP-25 series pumps came with a new style diaphragm which has an o-ring molded into the air side. This change was made for two reasons: To prevent air leaks where the diaphragm contacts the air chamber. To prevent a diaphragm from pulling out of place if there is excessive air pressure.
Oct 10, 2011 Paul Rainer
I often receive phone calls from end users about diaphragm cycle life and the first few questions I ask are: What pump are they using? What chemicals are they using and at what temperature? Is it a suction lift application or a flooded suction? At what flow rate are they operating the pump? After discussing these questions I find that several customers are running the pump at full throttle…
Apr 15, 2011 Paul Rainer
Yamada makes drum pumps in 3 port sizes. The 3/8” pump is available in Aluminum and Stainless Steel. The 1/2” pump is available in Polypropylene or Kynar. The 3/4” pump is available in Polypropylene, Aluminum or Stainless Steel.
Apr 15, 2011 Paul Rainer
Proximity Sensors can be provided on almost any Yamada pump. They are used to send a signal every time the pump completes a cycle. This signal can then be used to count cycles for preventative maintenance. It can also be used to monitor flow rate. Proximity Sensors can be provided on almost any Yamada pump. They are used to send a signal every time the pump completes a cycle. This signal can then…